06/16 Rev. 09
SERVICE MANUAL
Service Mechanics
DPM – PEM – ALX 92x
94
Retrofitting M5A output stages
Prerequisites
•
Feed-, headlift, ribbon motor:
Defective M4A output stages (article no.
A2742 or A6713) can be replaced by M5A
output stages, if the retrofitting kit is applied
that is offered for this purpose. Contents of
the retrofitting kit [199].
•
Rewinder motor (ALX 92x):
Defective M4A output stages for use with
the rewinder motor can only be replaced by
M5A output stages, if the following is the
case:
– Elektronics:
Gen. 3
(article no. of the
output stage board: A3036).
– Printer firmware: Version
6.37
or higher.
Retrofitting the output stage
1. Unplug all cables and remove the M4A
board.
2. Attach the M5A output stage board.
Use the hex socket screws contained in the
retrofitting kit [199B].
3. Connect the motor cable to the adapter
cable [199C]. Connect the adapter cableto
the output stage.
4. Reconnect the remaining 3 cables to the
output stage [200].
Continued overleaf.
[198] New (M5A) and old (M4A) output stage board.
[199] Retrofitting kit for M5A output stages (article no. A9836).
[200] Connections at the M5A output stage.
M5A
M4A
A
B
C
Motor
Sensor
(not with rewinder
output stage for
ALX 92x)
CPU board
Power supply
D
D
D
D
D
D
D
D
S
D
G
S
D
G
S
D
G
S
D
G
S
D
G
S
D
G
S
D
G
S
D
G
110
P2
P1
K9C
K2
K1
A
U400
DZ300
1
3
2
R310
R227
C236
R226
ST400
1
3
2
C230
R225
V I TE3
C233
R224
HOLE2
C239
BUS
H1
R244
R230
R246
R247
C226
C227
R228
R229
J4
4
1
U500
BUS
H2
QN207
3
2
1
QN206
12
3
QN205
3
2
1
QN204
3
2
1
QN203
3
2
1
QN201
3
2
1
QN200
3
2
1
D207
D206
D205
D204
JMP101
1
D200
HO
LE5
R207
R206
R204
C413
R423
R205
CRO
SS1
C400
U102
D202
R202
C220
U204
R201
C219
R219
R235
V I TE2
R232
R217
C200
V I TE1
HOLE1
R223
R239
R243
R222
R238
U203
D203
R203
C221
U202
R236
R220
R242
R221
R237
R233
R218
R241
R231
R216
R240
U200
R200
C218
D403
L400
12
U401
DZ400
U206
CRO
SS4
J2
13
14
1
2
LED100
JMP100
1
U300
U100
D201
U201
J12
CE400
CE401
CRO
SS3
D400
CE402
CE403
QN202
3
2
1
C231
C232
C234
C235
C237
C238
C240
C241
J3
4
1
U101
32
25
24
17
16
9
8
1
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...