06/16 Rev. 09
SERVICE MANUAL
Service Mechanics
DPM – PEM – ALX 92x
22
Retrofitting a Hall sensor
control unit (ALX)
Prerequisites
– Retrofitting kit A105985 (RH) or
A105984 (LH) [38]
– ALX 92x with „Gen. 3“ electronics and
CPU board A6621 with index -05 or hig-
her
– Firmware version 6.43
– Stepper motor output stage board M4A
(A2742) oder M5A (A7579)
The output stage board
R04A
, which used
to be built in before the change to the Hall
sensor, can
not
be used.
Stepper motor output stages: See topic
section
, section „M4A
output stage board“ or „M5A output stage
board“.
Tools
– 2 / 3 mm allen keys
– Feeler gauge (0.2 mm)
– Straight-edge
Dismantling the old sensor
The illustrations show a RH machine.
Cables are not illustrated.
1. Dismantle the rear hood.
2. See chapter
3. Disassemble the dancer lever [39A].
4. Remove the retaining washer [39B] from
the axle.
5. Rotate the axle so that the wedge doesn´t
engage in the light barrier fork. Pull out the
axle [40].
Continued overleaf.
[38] Retrofitting kit (RH).
[39] Dismantling the dancer lever (A).
[40] Dismantling the axle (A).
B
A
A
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...