05/16 Rev. 06
SERVICE MANUAL
Applicator Interface
ALX 92x – ALX 73x
Signal-Time-Diagrams
10
LTP und LTPV
[4] Pattern of control signals over time for LTP(V) applicators.
A
Duration is determined by label length and dispensing speed. „Airstream Support“ switching to low
means the label is dispensed.
B
Duration t is determined by the backwards movement of the applicator. The application cycle ends
when the home position signal is high again
C
Adjustable with
APPLICATOR PARA > Blow on time
.
D
The output signal „Offline“ follows the input signal „Inhibit“.
E
The start signal is ignored because of the active „Inhibit“.
t
Start signal
Home position
Airstream support
Cylinder
(setable)
Vacuum
Blow on
(setable)
Offline
Cycle
Inhibit
Touch down
B
D
A
C
E