Setting
7. Turn the connecting link [164A] to the
lowest position (printing position).
8. Clamp 0.1 mm thick material [165C] bet-
ween the connecting link and the pressure
arm [165B].
9. Loosen screw [166A] at the head lifting
motor. Turn the contact spring [166B]
aside.
(continued next page)
[164] Connecting link (A) on the mounted head lifting motor (ALX/
RH)
[165] Connecting link (A) on the dismantled head lifting motor.
A
Connecting link
B
Pressure arm
C
0.1mm thick material
A
B
C
B
A
[166] Kontaktfeder (A) an der Druckkopf-Andruckachse.