04/16 Rev. 11
USER + SERVICE MANUAL
/Status Reports
64-xx – DPM – PEM – ALX 73x (PMA) – LPA 81x (Printer) – ALX 92x – AP 5.4 – AP 5.6
74
9009 Temporary
MAC
Temporary
MAC
address.
Status
This error message is displayed, if the MAC address has the value
00.0a.44.00.00.00
. This MAC address is used only during production.
Measure
Acknowledge the status message by pressing the Online button. The
printer will be starting and the network can be used.
Contact the technical support for a new programming of the board´s MAC
address.
If a new programming is not possible, exchange the CPU board.
9011 Bootloader
ext.
Bootloader external device.
Status
At least one external device (e.g. AI, BLDC output stage) has no valid (e.g.
an incomplete) application program loaded. This is the reason, why the
device remains in the bootloading status and signalizes this status
message.The error can only occur, until now (05/04), if an AI is applied.
Measure
Load a valid application program.
9013 Head
voltage
Status
Faulty 5 V print head supply voltage. Possible causes are:
•
Only AP 5.4
: Printhead was connected to the wrong connector on the CPU
board.
•
Short circuit, possibly is the printhead defective.
Measure
Only AP 5.4
: Check if the printhead is connected to the correct connector
on the CPU board. Change the connector, if necessary.
Replace the printhead
9014 Motor
voltage
Status
Faulty 45 V motor supply voltage. A possible cause is a short circuit, that is
the printhead is defective.
Measure
Replace the printhead
9015
Network init.
Status
Error during the network initialization.
Measure
Contact your network administrator.
9016 DHCP
Failed
Status
DHCP failed. This may happen, if parameter
INTERF. PARAM. >
ETHERNET PARAM. > IP Adressassign
is set to
DHCP
, but no IP-address can be
drawn.
Measure
Contact your network administrator.
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...