05/16 Rev. 03
USER- / SERVICE MANUAL
Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
AP 4.4 – AP 5.4
64-xx – DPM – PEM – ALX 92x – ALX 73x (PMA)
104
Start mode
AP 5.4
Only if
SYSTEM PARAMETER > Periph. device
= „Dispenser“.
Determines the interpretation of a start signal at the foot switch jack.
Edge
(Default setting) The falling (low active) signal edge triggers the printing of ex-
actly one label.
Level low active
Labels of a certain print job are being printed as long as the signal level is
low. When using a foot switch, labels are printed as long as somebody keeps
the foot switch pressed.
Start source
64-xx
AP 5.4
AP 5.6
Only if
SYSTEM PARAMETER > Periph. device
= „Dispenser“.
Choose a signal source for the start signal:
Foot switch
Optional foot switch is used to generate the start signal.
Light barrier
(Default setting) Photoelectric switch at the dispensing edge which detects
the taking off of the dispensed label.
The setting "Light barrier" is unsuitable for product sensors! Product
sensors must be connected to the I/O board!
Dispensing edge
64-xx
Only if
SYSTEM PARAMETER > Periph. device
= „Dispenser“.
Adapts the feeding to the length of the dispensing edge.
long
Long dispensing edge
short
Short dispensing edge (Default setting)
User defined
The distance between print line and dispensing edge can be set by
SYSTEM PARAMETER > Head disp dist
(see below). This is helpful if none of the
standard dispensing edges are applied.
Max InitFeedback
64-xx
ALX 92x
DPM
64-xx: Only with dispenser version.
Only if
SYSTEM PARAMETER > Gap detect mode
= „Autom. feed back“.
During initialization, the label material is fed back until the next punch/reflex
mark is reached. This parameter defines the maximum admissible back-
wards feeding length.
xx mm
Setting range: 0 to 200 mm; Step width: 1 mm; Default setting: 80 mm
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...