04/16 Rev. 11
USER + SERVICE MANUAL
/Status Reports
64-xx – DPM – PEM – ALX 73x (PMA) – LPA 81x (Printer) – ALX 92x – AP 5.4 – AP 5.6
69
8700
IDM Data with 0
Status
Bar code IDM: data may not contain 0x0.
Measure
Correct data.
8701 IDM
Data
length
Status
Bar code IDM: Illegal length of data string.
Measure
Check length of the transmitted data and bring it to the permitted length.
8702 IDM
Coding
Status
Bar code IDM: coding error.
Measure
8703 IDM
Self-test
Status
Bar code IDM: error during self-test.
Measure
8704 IDM
Init.
error
Status
Bar code IDM: error during initialising.
Measure
8705 IDM
rows/columns
Status
The input data does not match the given matrix or the number of
rows/columns is invalid.
Measure
Change the number of rows/columns or the input data.
8760
EAN128 field len
Status
The number of data after a data identifier does not correspond to the
definition for this data identifier.
Measure
Change the number of data.
8761
EAN128 Data type
Status
The data type (alphanumeric, numeric) after a data identifier does not
correspond to the definition for this data identifier.
Measure
Change the data type.
8762 EAN128
Ident.
Status
Invalid data identifier.
Measure
Change the data identifier.
8800 Maxicode
Mode
Status
Maxicode: faulty mode
Measure
Change mode.
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...