5072 Material
end
unw
Status
Occurs during operation with activated
internal
OD control. The message
appears, if no rotation of the mate-rial roll has been registered during at
least 600 mm of material feeding.
Measure
Check the material feeding; if necessary, replenish the material roll.
5100
No H8 response
Status
Communication fault with H8 processor (occurs only at devices with Gen. 2
electronics).
Measure
Acknowledge by pressing the Online button.
Switch device off and on again.
If the message continues to appear:
Contact service technician.
Instructions for service technicians:
The error can occur in connection with the exchange of the CPU board of
an ALX 92x machine.
Acknowledge error, set all sensors, restart.
If the error message still appears: Reload firmware and/or carry out a
forced bootloader start with "Clear params".
If the error continues to appear: send CPU board with a fault description to
the manufacturer.
5100 Printengine
lock
Status
Printengine error (occurs only at devices with Gen. 3 electronics).
Measure
Acknowledge by pressing the Online button.
Switch device off and on again.
If the message continues to appear:
Contact service technician.
5101 Headadjust
error
Status
Error during the running of the "Head Alignment" service function.
Measure
Acknowledge by pressing the Online button.
Contact service technician.
5102 Dot
Defective
Status
Defective dot detected during the running of the "Head dot test" service
function.
Measure
Acknowledge by pressing the Online button.
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...