SERVICE MANUAL
Electrical connections
ALX 92x
15
Connecting the rotary encoder
No changeover is necessary for a Push-Pull rotary
encoder.
Connecting the recommended rotary encoders to an
M12 connector:
Recommended connector [27]:
•
Manufacturer
: Franz Binder GmbH
•
Order no.
: 713 1 99 1429 812 04
Connection diagram
[28] Connection diagram rotary encoder.
CAUTION!
To avoid damage to the electronics:
Switch the machine off before connecting
the rotary encoder.
Pin
Colour of wire
P F.
Colour of wire
Sick-Stegmann
Function
1
Brown
Red
+24 V
2
Grey
Pink
Impulse B
3
White
Blue
Ground
4
Green
White
Impluse A
[26] Pin assignment rotary encoder connection
[27] Recommended M12 connector (article number: A8142 for
cable-Ø 4-6 mm, A8143 for cable-Ø 6-8 mm)
Impulse B
GND
Impulse A
+24 V
1
2
3
4
+24V
+24V
Signal A
Signal B
3,2k
3,2k
1k
Signal A
Signal B
GND
1
4
2
3
to
CPU
PNP
PP
input
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...