06/16 Rev. 09
SERVICE MANUAL
Service Mechanics
DPM – PEM – ALX 92x
115
Connecting
1. Connect the cable [250A] that guides to
the rotary encoder jack to CN 1100 on the
CPU board [256A].
2. Connect the 2-wire voltage supply cable
[250C] with one end to CN 1400 on the
CPU board [256B].
3. Connect the loose end of the voltage sup-
ply cable to one of the two 24 V-connectors
[257A] at the power supply.
4. Reattach respectively close the rear hood.
[256] Connecting the internal cables to the CPU board A6621.
A
(CN 1100) Connector for rotary encoder
B
(CN 1400) Connector for cable to power supply
[257] 24 V connectors at ME500 (left) and HME (right) power
supplies.
A
B
A
A