05/16 Rev. 06
SERVICE MANUAL
Applicator Interface
ALX 92x – ALX 73x
Signal-Time-Diagrams
8
PEP Blow On / LA-TO BO timed
[2] Pattern of control signals over time for PEP Blow On applicators.
A
Duration is determined by label length and dispensing speed. „Airstream Support“ switching to low
means the label is dispensed.
B
The total duration of Cylinder is the sum of both durations t
1
and t
2
. The duration t
1
is setable by
APPLICATOR PARA > Dwell time
; t
2
is setable by
APPLICATOR PARA > Blow on time
(see note C).
C
Can be adjusted with
APPLICATOR PARA > Blow on time
.
D
Duration t
3
is determined by the backwards movement of the applicator. The application cycle ends
when the home position signal is high again.
E
The output signal „Offline“ follows the input signal „Inhibit“.
F
The start signal is ignored because of the active „Inhibit“.
A
B
C
E
D
F