05/16 Rev. 03
USER- / SERVICE MANUAL
Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
AP 4.4 – AP 5.4
64-xx – DPM – PEM – ALX 92x – ALX 73x (PMA)
150
Send test
64-xx
ALX 92x
DPM
PEM
ALX 73x (PMA)
AP 4.4
AP 5.4
AP 5.6
Serial connection
Carrying out the send test requires a terminal program, e.g. the Hyper Termi-
nal contained in Windows95.
Start send test as follows:
1. Start the terminal program and set it to the transmission parameters used by
the printer.
2. Press the Online-key to start the send test.
[21] Pattern in the terminal window.
The terminal window should show a regular pattern of four repeating charac-
ters. Those characters are continuous sent by the printer.
A transfer fault would be recognizable as irregularity of the pattern. Press the
Prog-key to stop testing.
Send test
running . . .