12/14 Rev. 05
SERVICE MANUAL
Service Electronics
64-xx Gen. 2 – DPM Gen. 2 – ALX 92x Gen. 2
47
Sensor test
General notes
Activating the sensor test: call parameter
SERVICE FUNCTION > Sensor test
.
By means of the sensor test, you can check the function of each sensor:
•
If the value shown on the printer display exceeds the range given in the chart
below, the respective sensor is possibly dirty and has to be cleaned (blow the
dirt off with compressed air).
•
Check the function of light barriers by covering it, and of micro switches by
triggering it. If the displayed value doesn´t change when the sensor is
covered or switched, it is possibly or defective.
•
Sensors which are not connected show values about 255 in the sensor test.
•
General rule for all sensor values:
– Full light leads to values <= 10
– No light leads to values >= 220
•
To sensors which function as a switch applies the following: Values between
10 and 220 mean that the sensor is poorly set, dirty or close to the end of its
life.
[9] Display after calling „Sensor test“.
Extraneous light must be avoided when checking the sensors. Therefore,
keep the front cover and the housing cover closed during the sensor test.
After starting the sensor test, the following is displayed:
Press the Feed or Cut button („Apply“ button with ALX/DPM/PEM) to select
the individual sensors (if present).
For details refer to paragraph
If the following message shows up, a communication error occured between
the CPU board and the motor driver board belonging to the sensor:
Sensor test
0.01 Option 255
0.01 = Sensor ID, Option = Sensor designation, 255 =
Sensor setting
Sensor test
No sensor found
Sensor test
0.01 Punch 11
Value
Sensor name
Sensor #
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...