06/16 Rev. 09
SERVICE MANUAL
Service Mechanics
DPM – PEM – ALX 92x
72
Fit the cylindrical moulding [148A] into
the groove on the guiding profile [148B].
Dismantling (PEM)
1. Open the rear hood.
2. Remove the cable straps from the sensor
cable [149A] and disconnect the cable
from the CPU board.
3. Remove the guiding profile.
4. Remove the screw [150B] underneath the
punch sensor thumb wheel [150A].
5. Pull out the punch sensor assy. [151A].
[148]
A
Cylindrical moulding on the sensor fitting
B
Groove on the guiding profile
B
A
[149]
A
Connection cable punch/reflex sensor (PEM LH)
A
[150] Fixing screw (B) of the punch sensor assy. (View from the
bottom side)
B
A
[151] Pulling out the punch sensor assy. (A) (PEM LH).