04/16 Rev. 11
USER + SERVICE MANUAL
/Status Reports
64-xx – DPM – PEM – ALX 73x (PMA) – LPA 81x (Printer) – ALX 92x – AP 5.4 – AP 5.6
36
4105
No OLV response
Status
This error may occur shortly after switching on the printer with the OLV
device already switched on. It indicates, that the OLV version number was
not successfully read.
Possible causes are:
•
Wrong connection cable between OLV and printer
•
Faulty interface parameter setting for Com2
•
Power supply of the OLV interrupted or not available
•
Defective I/O board (Com2)
Measure
Check the possible causes of failure and exchange defective parts.
4106 OLV
Software
Status
General software error
Measure
Please read the notes in section
.
5000 Bus
device
Status
One of the devices connected to the I
2
C bus (e.g. output stage boards)
does not respond. This message appears mostly first in a sequence of two
or three status messages, which help to isolate the error source.
Measure
Acknowledge by pressing the Online button.
Switch printer off and back on again after 30 sec. If the error message
continues to appear, please contact the manufacturer.
Example
The
parameter
SYSTEM PARAMETERS > Periph. device
is set to "Cutter" without
an output stage board for a cutter being installed. The following status
messages appear one after another:
1. Status 5000
Bus device
Generally tells, that something went wrong
with I
2
C bus communication.
Press Online button.
2. Status 5005
Knife-fault
Either no output stage board is prepared to
drive a cutter, or the I
2
C bus data cable is not
connected to the output stage board (this
message appears only in one of those two
cases, alternative status messages see Tab.
2)
Press Online button.
3. Status 5020
I2C Timeout 4
Time limit exceeded without getting an answer
from device no. 4 (4 = Cutter, see Tab. 4)
(alternative status messages see Tab. 3)
Press Online button
One of the following status messages may follow second:
Status # Text
Missing output stage for the following
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...