06/16 Rev. 04
SERVICE MANUAL
Service Electronics Gen. 3
64-xx Gen. 3 – DPM Gen. 3 – PEM – ALX 92x Gen. 3 – ALX 73x (PMA)
21
M5A output stage board
Application notes
The M5A output stage is integrated into all print & apply machines (ALX,
DPM, PEM) since 1/2012.
Required firmware version:
– DPM, PEM, ALX 92x: 6.37Post6811 or higher
– ALX 73x(PMA): 6.39SR1 or higher
With the M5A output stage, both motor type as well as motor rotation directi-
on (RH/LH machine) are subject to jumper setting (in contrast to the M4A,
where only the motor type has to be set).
The M5A output stage can be retrofitted into older machines (installation in-
struction see topic section „Service mechanics“, chapter „Boards“ > „Retrofit-
ting M5A output stages“.
View
[3] Endstufen-Platine M5A.
A
Mounting bracket
B
Jumper for setting the rotation direction (JP101)
C
Sensor connection
D
Jumper for setting the motor type (JP100)
E
Motor connector
F
Connector CPU board (data line)
G
Connector power supply
A
B
C
D
E
F
G
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...