06/16 Rev. 09
SERVICE MANUAL
Service Mechanics
DPM – PEM – ALX 92x
21
Dancer lever Hall sensor (ALX)
In ALX 92x which were built later than 09/
2013, the position detection of the dancer
lever is done by a Hall sensor. This implies
the following advantages:
– Improved resolution
– No potentiometer setting required
– Immunity to ambient light and dust
– Improved long term stability
Tool
– 2 mm allen key
Dismantling
1. Dismantle the rear hood.
2. See chapter
3. Disconnect the cable at the sensor board
4. Unscrew two screws [36B]. Remove sen-
sor board.
Assembly
Make sure to:
Position the screws [36B] central in the
long holes in the board.
If the sensor cable was disconnected:
Connect the sensor cable to the CPU
board [37A]:
– M5A output stage: CN1111 [37B]
– M4A output stage: CN1110 [37A]
Set the Hall sensor.
See topic section
,
section „Settings“.
[36] Hall sensor (in RH machine).
[37] Connecting the sensor cable.
A
CN1110: Operation with M4A output stage board
B
CN1111: Operation with M5A output stage board
A
B
A
B
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...