05/16 Rev. 03
USER- / SERVICE MANUAL
Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
AP 4.4 – AP 5.4
64-xx – DPM – PEM – ALX 92x – ALX 73x (PMA)
45
x
Setting range: 1 to 10; Unit interval: 1; Default setting: 1
The printed bar code height calculates starting with the value defined in the
label layout multiplied by the scaling factor x.
Tradit. Imaging
64-xx
ALX 92x
DPM
PEM
ALX 73x (PMA)
AP 4.4
AP 5.4
AP 5.6
In production mode only.
Up to firmware version x.31, the barcode height was calculated with the
formula:
with x =
PRINT PARAMETERS > Barcode Multi.
By doing so, the printed barcode height in millimeters was by 1 higher than
the value defined in the layout (1 --> 2 mm, 2 --> 3 mm, etc.)
1)
.
From firmware version x.31 on, the printed barcode is exactly as high in mil-
limeters, as the value in the layout is (1 --> 1 mm, 2 --> 2 mm, etc.)
.
No
New height calculation (1 --> 1 mm, 2 --> 2 mm, etc.) is applied (default set-
ting).
The plain copy line is printed with OCR-B font.
Yes
Setting for customers with print layouts based on the
old
height calculation
scheme.
The plain copy line of the barcodes EAN8, EAN13, UPC-A and UPC-E is prin-
ted with the same fonts, which older printer types like TTK or TTX x50 have
used.
UPC plain-copy
64-xx
ALX 92x
DPM
PEM
ALX 73x (PMA)
AP 4.4
AP 5.4
AP 5.6
The position of the first and last digit in the plain-copy line - underneath the
bar code - can be adjusted as required.
Raised
First and last digit of the UPCA or first digit with the UPCE are raised (default
setting).
In line
All digits in the decoded line are in line under the code.
EAN Readline
64-xx
ALX 92x
DPM
PEM
ALX 73x (PMA)
AP 4.4
AP 5.4
AP 5.6
<> Signs
Readline enclosed in "<>" signs or terminated by a ">"-Sign (EAN 13).
Standard
Readline without "<>" or ">" signs (default).
1) Assumed that
PRINT PARAMETERS > Barcode Multi.
= „1“.
Barcodehight
Barcodehight
Layout
1
+
x
=
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...