05/16 Rev. 06
SERVICE MANUAL
Applicator Interface
ALX 92x – ALX 73x
Interface description
22
Circuit diagrams for signal outputs
All signal outputs are designed as PNP and are galvanically separated from
the 5 V control system (optocoupler).
[17] Main circuit for outputs (PNP).
Signal outputs
Signal outputs are mainly used for connecting to other devices or to machine
controls.
Admissible resistive load:
240 Ohm @ 24 VDC.
Maximum admissible output current for each signal output: 0.1 A.
24 V
Load
GND
GND
Applicator Interface
5 V
Quantity
Value
Note
Supply voltage
24 V ±10%
Voltage drop at V
OH
0.3 V @ 0.1 A
t
pLH
1 µs
Rise time „0“
„1“
at 240 Ohm
t
pHL
1 µs
Fall time „1“
„0“
at 240 Ohm
t
delay
30 µs
5 V microcontroller output
24 V output
[Tab. 4] Switching levels of power outputs.