06/16 Rev. 04
SERVICE MANUAL
Service Electronics Gen. 3
64-xx Gen. 3 – DPM Gen. 3 – PEM – ALX 92x Gen. 3 – ALX 73x (PMA)
63
Preparing the light barrier sensor cable
Steps 4, 5 and 6: The contact springs
[50A][51A] must engage in the bushing
housing cutouts [50B][51B]!
4.
Insert the brown
lead of the light barrier
sensor cable into the 4-pin bushing
housing as shown [50].
5.
Insert the blue
lead of the light barrier
sensor cable into one of the 1-pin bushing
housings as shown [51].
6.
Insert the black
lead of the light barrier
sensor cable into the other 1-pin bushing
socket in the same way.
7. Thread the light barrier sensor cable leads
[52A] through the opening in the housing.
8. Lead the board plate mounted on the light
barrier sensor cable [52B] through the
opening in the housing, rotating it slightly.
9. Screw the plate board [53A] onto the
housing (2 screws).
The photo [53] shows assembly on a RH
machine. On LH machines, the plate board
is mounted rotated through 180×!
Continued overleaf.
[50] Insert the spring contact into the 4-pin bushing housing.
[51] Insert the spring contact into the 1-pin bushing housing.
[52] Insert the board plate into the side panel through the open-
ing.
[53] Screw on the board plate (ALX/RH).
A
B
A
B
A
B
A
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...