05/16 Rev. 03
USER- / SERVICE MANUAL
Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
AP 4.4 – AP 5.4
64-xx – DPM – PEM – ALX 92x – ALX 73x (PMA)
122
•
Start print error
•
Other errors, which keep the printer from printing
During the initialization (powering up) of the printer, the ERROR-signal is
instable!
Prin Offl
In addition to the above mentioned cases avtivate the following events the
ERROR-signal:
•
The printer is in offline mode
•
The printhead pressure lever is open
•
„I/O board pause“ mode
•
Stopped mode (the printing was stopped)
Error Polarity
64-xx
ALX 92x
DPM
PEM
ALX 73x (PMA)
AP 5.4
AP 5.6
Only with an I/O board mounted.
Switches the polarity of the ERROR signal.
Level high activ
The output is high when it is active, otherwise low.
Level low active
The output is low when it is active, otherwise high. (Default)
Status output
64-xx
ALX 92x
DPM
PEM
ALX 73x (PMA)
AP 5.4
AP 5.6
Only with an I/O board mounted.
This parameter defines different events, which activate the output signal
MACHINE STATUS.
Low ribbon warn
The signal is activated, if the ribbon roll diameter is less than the limit.
Print job ready
(Default setting) The signal is activated, if the printer has finished image pro-
cessing and is ready to start printing.
The signal is
not activated
, if:
•
the print job is done,
•
the print job was stopped,
•
the printer was switched to offline mode,
•
the printer is in pause mode.
Status polarity
64-xx
ALX 92x
DPM
PEM
ALX 73x (PMA)
AP 5.4
AP 5.6
Only with an I/O board mounted.
Switches the polarity of the MACHINE STATUS signal.
Level high activ
The output is high when it is active, otherwise low.
Level low active
(Default setting)The output is low when it is active, otherwise high.
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...