06/16 Rev. 04
SERVICE MANUAL
Service Electronics Gen. 3
64-xx Gen. 3 – DPM Gen. 3 – PEM – ALX 92x Gen. 3 – ALX 73x (PMA)
76
2. Check, if the displayed value (xxx) lies below 50.
3. If the value doesn´t lie below 50: Unscrew the sensor board and rotate it for
some degrees [7]. Retighten the sensor board.
RH: rotate clockwise
LH: rotate counter-clockwise
[7] Decrease the value in the resting position by turning the sensor board in arrow direction:
4. Repeat steps 2 and 3 until approx. 30 is displayed.
A value below 25 indicates that the sensor is probably installed off-centre [8].
[8] Inadmissible mounting position - the sensor middle is not centred!
RH
LH
RH
LH