06/16 Rev. 09
SERVICE MANUAL
Service Mechanics
DPM – PEM – ALX 92x
93
Stepper motor output stages
Since 1/2012, the PMA is delivered with the
newly developped M5A output stages,
which replace the M4A output stages,
which were built-in previously [196]. Ma-
chines, which have been assembled before
1/2012 can be retrofitted with M5A output
stages.
Retrofitting M5A output stages: see chap-
ter
Retrofitting M5A output stages
Each of the three end stage circuit boards
[197] controls one of the three stepper mo-
tors. Each board forms a unit with a heat
sink. The heat sinks are each attached to
the machine´s base plate with two screws.
Tools
•
3 mm Allen key
•
Torx screwdriver size 15 (machines built
until 6/2006)
Dismantling
1. Open (DPM/PEM) or dismantle (ALX)
the rear hood.
2. Disconnect the cable from the board.
3. Undo the fastening screws (2 screws) on
the board heat sink. Remove the board.
Assembly
To assemble the device, follow the steps in
the reverse order. Make sure to
Check any new output stage board be-
fore mounting:
– (M4A) Circuit board version
– (M4A) PIC version
– (M4A, M5A) Jumper setting for motor
type
– (M5A) Jumper setting for rotation
direction (RH/LH machine)
Jumper settings
and
pin assignments
can
be found in topic section
"Output stage board".
[196] New (M5A) and old (M4A) output stage board.
[197] Stepper motors and the corresponding output stages
(ALX 924).
A
Head lifting motor
B
Ribbon motor
C
Feed motor
D
(ALX 92x) Rewinder motor
M5A
M4A
A
B
C
D
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...