07/15 Rev. 03
SERVICE MANUAL
Electrical connections
ALX 92x
11
Connecting sensors
A product sensor can optionally be connected to
the USI or to the AI interface. Due to the en-
hanced setting options (choice between error or warn-
ing message), the connection to USI is recommended.
Because AI and USI cannot be driven both at a time,
the sensor has to be connected to the AI, if the ALX 92x
is operated with an applicator.
Product sensor at USI
Prerequisite
: Machine is equipped with optional signal
interface (USI).
• Permitted sensor type: NPN
• Order no.: A2682 (readily assembled NPN sensor
for connection to USI [17])
Connection diagram for USI: See service manual, topic
section
, chapter „USI board“ >
„Circuit diagrams for signal inputs“.
WARNING!
This unit operates at mains voltage! Contacting electrically live components can cause
lethal electrical shocks and burns.
The machine must only be connected with other machines if they meet the require-
ments of a SELV circuit (Safety Extra-Low Voltage circuit) in accordance with
EN 60950.
[17] Product sensor for ALX 92x (photoelectric switch, NPN,
connector fits USI, Datasensor S50-PA-2-C10-NN, article no.
A2682).
[18] Connecting the product sensor (B) to the USI (A).
A
B
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...