06/16 Rev. 09
SERVICE MANUAL
Service Mechanics
DPM – PEM – ALX 92x
99
Exchanging the ME500 power
supply
Tools
•
2.5/3mm allen key
•
Small/medium cross-head screwdriver
•
Hex socket wrench, size 5.5
•
Side-cutting pliers
Dismantling
1. Open the rear hood.
2. Detach all cables from the power supply.
Open the cable clamps [207A] and sepa-
rate the cable ties. Remove the cables
from the cable clamps.
3. Unscrew the PE cable [213A] at the
housing.
4. Turn out the upper fixing screw at the fan
5. Remove the lower fixing screws (4 pieces)
from the rear hood bottom. Take off the
dust filter [215A].
6. Remove the power supply.
7. Unscrew the fixing bracket from the power
supply.
Assembly
Follow the description in the following
chapter starting with
WARNING!
Hazard caused by dangerous
contact voltage!
After switching off the printer, wait
at least 1 minute before touching
any electric contacts at the power
supply.
[212] Netzteil ME500 power supply.
[213] Detach the cables from the fastenings (left: LH; right: RH).
[214] Fixing to the fan (here: LH).
[215] Fixing to the rear hood bottom.
A
A
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...