06/16 Rev. 09
SERVICE MANUAL
Service Mechanics
DPM – PEM – ALX 92x
100
Retrofitting a ME500 power
supply
Until approx. 03/2014, the HME PS 450 po-
wer supply (brief „HME“) was installed in
DPM/PEM machines, afterwards the
ME500 power supply took its place. If a
HME turns out to be defective in the future,
it must be replaced by a ME500. Regarding
the electrical connections, this can easily
be done. The machanic integration requi-
res some additional parts, which are conta-
ined in a retrofitting kit [216].
Further information can be found in topic
section
, "Power
supplies".
The exchange procedure can be devided
into the following steps, which are descri-
bed in detail in the following:
1. Dismantling the defective HME.
3. (RH only) Preparing the housing.
Tools:
•
2.5/3mm allen key
•
Size 1 and 2 cross-head screwdrivers
•
Hex socket wrench, size 5.5
•
Side-cutting pliers
Dismantling the defective HME
For instructions see chapter
Preparing the new ME500
1. (If the bracket is mounted) unscrew the
fixing bracket [216I].
2. Use the screws and lock washers from
step 1 to screw the fixing bracket [216F] to
the power supply as illustrated [217A].
The fixing bracket must touch the long side
of the power supply.
3. Stick the two cable clamps to the power
supply as illustrated [217B].
4. (RH only) Stick the two cable sockets to
the power supply as illustrated [217C].
[216] Scope of delivery of the ME500 retrofitting kit (A100145).
The orange marked parts are not necessary for installation in
the DPM/PEM.
A
ME500 power supply
B
Cable ties (3x 100x2,5)
C
Cable sockets
D
Cable clamps
E
Countersunk screw (DIN 7991 M4x30)
F
Fixing bracket
G
Serrated lock washer (2x M3)
H
Screws (2x M3x5)
[217] ME500 ready prepared.
A
B
C
D
E
F
H
G
I
LH
RH
B
A
C
D
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...