06/16 Rev. 09
SERVICE MANUAL
Service Mechanics
DPM – PEM – ALX 92x
103
Connecting the ME500
1. Screw the PE cable to the housing
Assembly sequence: serrated lock
washer - eyelet - serrated lock washer -
nut.
2. Remove the jumper from the connector
3. Connect the cables as illustrated [227].
Recommended sequence: alphabetically,
following the position letters.
4. Fix the cables as pictured in the following
chapters.
5. Check, if the cables are connected pro-
perly and if they are fixed.
6. Close the rear hood of the machine.
7. Check the machine according to the regu-
lations which are relevant in your country
1
.
WARNING!
Hazard caused by dangerous
contact voltage!
Attach the PE cable to the machine
housing.
After assembling, check the machi-
ne according to the regulations
which are relevant in your
country
1) Relevant in Germany: DIN VDE 701-702 about "repair, modi-
fication and inspection of electrical equipment"
[225] (LH only) Connecting the PE cable (A) to the housing.
[226] (RH only) Connecting the PE cable (A) to the housing.
[227] Connecting the ME500.
A
Remote on/off cable (2-pole, white, A3320)
B
Data cable (multicolored, A1074)
C
Fan (2-pole)
D
CPU board (3-pole, A2713)
E
Printhed (6- resp. 8-pole)
F
Motor output stages (6-pole, A1148)
A
A
F
D
B
A
C
E
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...