06/16 Rev. 04
SERVICE MANUAL
Service Electronics Gen. 3
64-xx Gen. 3 – DPM Gen. 3 – PEM – ALX 92x Gen. 3 – ALX 73x (PMA)
74
[5] Setting potentiometer (A) of the dancer lever sensor (B).
4. Move the dancer lever to the
loose
end [4]. Press the Apply button.
Display:
5. Move the dancer lever to the
tightened
end [4] and hold it there. Press the
Online button.
6. Restart the device.
The sensor is ready set.
Rewinder adjust
tightened xxx
A
B