06/16 Rev. 04
SERVICE MANUAL
Service Electronics Gen. 3
64-xx Gen. 3 – DPM Gen. 3 – PEM – ALX 92x Gen. 3 – ALX 73x (PMA)
73
Sensor setting
(M5A; 1/2012 --->)
Prerequisites:
• Rear hood is dismantled
• Backing paper is removed from the rewinder
• Light sensor is connected to the CPU board (see chapter
[4] Setting positions of the rewinder dancer lever
Setting:
During the setting, make sure, that no extraneous light is falling on the dancer
lever sensor [5B].
1. Call
SERVICE FUNCTIONS > Rewinder adjust
. Display:
Move the dancer lever to the
loose
end.
2. Move the dancer lever from the
loose
end to the
tightened
end. While doing
so, watch the value xxx. Check, if the values match the scheme pictured in
[4].
3. If the values don´t match the scheme: Set the potentiometer [5A] so that xxx
at the
tightened
end is at least
80
increments higher than the value at the
loose
end.
If the required value cannot be achieved by setting the potentiometer, there
is the option of reducing the LED current (see chapter
Dancer lever
Sensor value
Loose
xxx
Tightened
xxx + 80
[Tab. 2]
Overview: Sensor values with loose and tightened dancer lever.
Rewinder adjust
loose xxx
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...