06/16 Vers. 05
USER + SERVICE MANUAL
Technical Data
DPM – PEM – ALX 92x
19
Operation
Operation panel
• (DPM Gen. 2 / ALX 92x Gen. 2)
– 4-key control panel
– 2-line, 32-figure, illuminated LCD display (5 mm character height)
• (DPM Gen. 3 / PEM / ALX 92x Gen. 3)
– 5-key control panel
– graphical, 128 x 32 Dot, illuminated LCD display
Settings
Definition of parameters using menu or Easy Plug commands
Status messages / Test functions
Test printouts
Printouts for parameter settings, adding logo and font, line and bar code library
Test functions
Print tests, test routines for memory and sensors, interface test
Error reports
Display of error reports on the display, continuation of print jobs without label loss
Warnings
Ribbon roll nearly used up
Dot check
Checks the printhead on defective dots – automatically or manually
Certificates and Markings
CE, TÜV-Mark,
C
TÜV
US
-Mark, FCC, EAC, CCC
The regulation EN 55022 demands for class A devices the following text to be printed
in the manual:
The FCC regulation demands the following information text for class A devices:
IC (Industry Canada) requires the following wording for Class A devices:
„WARNING: This is a class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to take adequate
measures.“
„NOTE: This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are desi-
gned to provide reasonable protection against harmful interference when the equip-
ment is operated in a commercial environment. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interferen-
ce in which case the user will be required to correct the interference at his own ex-
pense.“
„CANADIAN D.O.C. WARNING This digital apparatus does not exceed the Class A
limits for radio noise emissions from digital apparatus set out in the Radio Interferen-
ce Regulations of the Canadian Department of Communications.“
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...