05/16 Rev. 06
SERVICE MANUAL
Applicator Interface
ALX 92x – ALX 73x
Signal-Time-Diagrams
11
PEP II sensor / LA-TO sensor / LA-TO BO Sensor
[5] Pattern of control signals over time for PEP II sensor and LA-TO sensor applicators.
A
Duration is determined by label length and dispensing speed. „Airstream Support“ switching to low
means the label is dispensed.
B
Duration t is determined by the backwards movement of the applicator. The application cycle ends
when the home position signal is high again.
C
Adjustable with
APPLICATOR PARA > Blow on time
.
D
The output signal „Offline“ follows the input signal „Inhibit“.
E
The start signal is ignored because of the active „Inhibit“.
t
Start signal
Home position
Airstream support
Cylinder
(setable)
Vacuum
Blow on
(setable)
Offline
Cycle
Inhibit
Touch down
B
D
A
C
E
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...