06/16 Rev. 04
SERVICE MANUAL
Service Electronics Gen. 3
64-xx Gen. 3 – DPM Gen. 3 – PEM – ALX 92x Gen. 3 – ALX 73x (PMA)
72
[2] Setting positions of the rewinder dancer lever
(schematic; ALX 92x LH; for rewinders driven by a R04A output stage)
3. If the values don´t match the scheme: Set the potentiometer [3A] so that xxx
in the
middle
is at least
90
increments higher than the value with the dancer
arm at the
loose
end.
[3] Setting potentiometer (A) of the dancer lever sensor (B).
If the required values are
not
successfully setable, the sensor board must be
replaced.
See topic section
, section „Material transport“, „Dancer lever
sensor“.
If the showed values are correct:
4. Move the dancer lever to the
loose
end [2]. Press the
Apply button
.
Display:
5. Move the dancer lever to the
middle
[2] and hold it there. Press the
Online
button
.
6. Restart the device.
The sensor is ready set.
Rewinder adjust
middle
xxx
xxx + min. 90
xxx
Stopper
Stopper
middle
loose
A
B
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...