12/14 Rev. 05
SERVICE MANUAL
Service Electronics
64-xx Gen. 2 – DPM Gen. 2 – ALX 92x Gen. 2
44
Settings
Sensor setting
The button designations mentioned in this description count only for 64-xx
printers. With DPM, PEM or ALX 92x, please press the
Apply
button instead
of the
Cut
button!
LS
LS means light sensor.
Proceed as follows to set the sensors:
1. Switch on the printer while you keep the Feed and Prog buttons pressed for
approx. 5s. After the printer has started, „Enter code“ is displayed.
2. Press the following buttons one after the other:
Cut, Online, Feed, Cut, Online, Online, Online
.
3. Call the parameter
SERVICE FUNCTION > Sesor adjust
.
Material-end-LS
This text is displayed:
The number on the
left side
is the setting value of the LED current
(standard: 220).
The number on the
right side
is the value measured by the sensor
(here: 255).
The higher the setting value, the lower is the measured value.
4. Remove the label material from the material-end-LS. The measured value
should now change to 0. If not, increase the setting value to 220.
5. Decrease the setting value by pressing the Cut button, until the measured
value changes to 255.
6.
64-xx
: Increase the setting value by 30.
DPM/PEM/ALX 92x
: Increase the setting value by 5.
The measured value changes to 0.
7. Insert some label material. The measured value should now be 255.
The punch may not be recognized as material end! If this is the case, adjust
the setting once more!
8. Press the online button to save the setting value.
Punch LS
Now, the settings of the punch sensor are displayed:
The number on the
left side
is the setting value of the LED current
(default: 70).
The number on the
right side
is the value measured by the sensor (here: 12).
9. Insert some backing paper of standard label material (with the labels peeled
off), to check the sensor measurement.
Inserting material means here inserting a material sample into the LS fork.
The material sample must be big enough to cover the LS!
10. Set the setting value to 75 ±5 by pressing the Cut or Feed button
respectively. The measured value should match the range of 11..25.
Sensor adjust
220 Matend 255
Sensor adjust
70 Punch 12
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...