12/14 Rev. 05
SERVICE MANUAL
Service Electronics
64-xx Gen. 2 – DPM Gen. 2 – ALX 92x Gen. 2
20
Circuit diagrams for signal inputs
[6] Main circuit for signal inputs (NPN) at the USI interface (here: connecting a start sensor).
Timing waveform of
input signals
The following criteria must be matched by the input signals of the USI:
Only one signal at a time may be switched active!
The input signals must switch bounce-free!
[7] Examples of timing waveform for the USI inputs.
Store to reprint last label
(if reprint functionality is
enabled)
No reprint because of
Pause-mode!
min. 10ms
Pause-mode off
min. 10ms
Pause-mode on
min. 10ms
min. 10ms
min. 10ms
Pause
min. 10ms
print 1 label
Feed
print 1 label
min. 10ms
min. 10ms
min. 10ms
min. 10ms
min. 10ms
print 1 label
min. 10ms
min. 10ms
min. 10ms
min. 10ms
min. 10ms
min. 10ms
(Puls mode both edges)
reprint last label!
min. 10ms
min. 10ms
print 1 label
(Puls mode falling edge)
min. 10ms
min. 10ms
min. 10ms
start feeding
labels
Reprint
Start Print
imprinting of the
previous label must
be finished!
min. 10ms
min. 10ms
Feed
stop feeding
labels
min. 10ms
min. 10ms
Reprint
print 1 label
min. 10ms
min. 10ms
Pause
reprint last label
(if not disabled)
imprinting of the previous
label must be finished!
Start Print
imprinting of the
previous label must
be finished!
imprinting of the
previous label must
be finished!
imprinting of the
previous label must
be finished!
imprinting of the
previous label must
be finished!
print 1 label
Pause-mode on
start feeding
labels
stop feeding
labels
Pause-mode off
print 1 label
reprint last label
(if not disabled)
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...