07/15 Rev. 02
SERVICE MANUAL
Fault Location
DPM – PEM – ALX 92x
3
Gap detection
See topic section
, chapter „Sensor test“.
Material transport
Ribbon, ribbon guide
Problem
Possible cause
Solution
Gap detection not pos-
sible
Photoelectric switch defective
Check with
SERVICE FUNCTION > Sensor test
, if
necessary replace the photoelectric switch
Photoelectric switches set in-
correctly
Use
SYSTEM PARAMETER > Sens. punch-LS
to alter
sensitivity
False photoelectric switch
selected
Select "Punched" or "Reflex" using
SYSTEM PARAMETER > Light sens. type
Print position shifted in
or against print direction
Gap position not recognised
consistently due to gap
contour
Correct photoelectric switch zero line using
PRINT PARAMETERS > Punch offset
[Tab. 3] Possible faults caused by the gap detection
Problem
Possible cause
Solution
No feed function
Stepper motor plug loose
Check and if necessary plug in
Stepper motor defective
Check and if necessary replace motor
CPU board defective
Check and if necessary replace mainboard
Feed button defective
Check and if necessary replace display board
Jolted print image
Material unwinder blocked
Check and if necessary loosen
Material shifts
Material guide set incorrectly
Check and if necessary set
(ALX 92x) Backing pa-
per rewinder runs conti-
nuously or never runs
Rewinder control needs
adjustment
Adjust the rewinder control, see topic section
, chapter „Settings“..
(ALX 92x) Backing pa-
per tears off
(ALX 92x) Backing pa-
per rewinder initializes
when closing the hood.
The rewinder dancer position
was changed, while the hood
was opened.
Don´t move the rewinder dancer arm, while the
front hood is open.
[Tab. 4] Possible faults caused by material transport
Problem
Possible cause
Solution
Unfounded ribbon end
message
Ribbon unwind mandrel is not
turned
Fix core to mandrel (spring plate), shift spring pla-
te if the thread has stripped.
Photoelectric switch defective
Check and if necessary replace (see also parame-
ter
SERVICE FUNCTIONS > Sensor test
)
Ribbon is not being rol-
led up
Ribbon core slips through
Fix core to mandrel (spring plate), shift spring pla-
te if the thread has stripped.
Toothed belt defective
Check and if necessary replace the belt
[Tab. 5] Possible faults caused by the ribbon guiding
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...