05/16 Rev. 03
USER- / SERVICE MANUAL
Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
AP 4.4 – AP 5.4
64-xx – DPM – PEM – ALX 92x – ALX 73x (PMA)
85
After acknowledging the first occured Easy-Plug error, the printjob and the
spooler are deleted (as by #!CA). This prevents the printing of labels with for-
mat errors.
Single job mode
64-xx
ALX 92x
DPM
PEM
ALX 73x (PMA)
AP 4.4
AP 5.4
AP 5.6
In single job mode (also stop mode) the printer stops after every job and waits
until the operator restarts the print process.
Off
Single job mode is switched off (default setting).
On
Single job mode is switched on. The printer always displays "Start next job",
before starting a new print job. This requests the user to acknowledge by
pressing the Online button.
Head resistance
64-xx
ALX 92x
DPM
PEM
ALX 73x (PMA)
AP 4.4
AP 5.4
AP 5.6
For optimum print quality, the individual print head resistance of the thermo
head employed in the device must be set once with this parameter.
When replacing the print head, the resistance value of the print head (to be
read off from the print head) must be entered again.
The value set here remains when the factory settings are carried out.
xxxx Ohm
Setting range: 1000 to 1500 Ohm; Unit interval: 1 Ohm
Setting the print head resistance:
Setting:
1. From the print head, read off the resistance value to be set and make a note
of it (1000 to 1500).
2. In off-line mode press the Prog. button, display:
PRINT INFO
.
3. Press the Cut button until
SYSTEM PARAMETER
is displayed.
4. Press the Online button, display:
5. Press the Cut button until the following is displayed:
6. Press the Online button, set value is displayed.
CAUTION!
Entering a false value can damage the print head.
Read off the correct value from the print head and set it accordingly.
SYSTEM PARAMETER
Foil end warning
SYSTEM PARAMETER
Head resistance
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...