04/16 Rev. 11
USER + SERVICE MANUAL
/Status Reports
64-xx – DPM – PEM – ALX 73x (PMA) – LPA 81x (Printer) – ALX 92x – AP 5.4 – AP 5.6
67
8305
Bar code print
Status
Error during calculation of the bar code print image.
Measure
Acknowledge by pressing the Online button.
Measure
Check whether the transmitted data is permitted for the bar code type; if
necessary alter the data.
8306 Plain-copy
len.
Status
Illegal: bar code plain-copy line has more than 300 characters.
Measure
Reduce line length.
8307 Readline
dist.
Status
General software error.
Measure
Switch printer off and then back on again after thirty seconds.
Please read the notes in section
.
8308
Bar code ratio
Status
Illegal bar code ratio.
Measure
Select another ratio.
8309 Module
range
Status
Maximum range of the bar code module exceeded.
Measure
Reduce module range.
8310
Bar code element
Status
Bar code element exceeds the maximum permitted size of 253 dots
(21 mm).
Measure
Reduce size of the bar code element.
8311 Barcode
table
Status
General software error.
Measure
Switch printer off and then back on again after thirty seconds.
Please read the notes in section
.
8400 PDF417
ECC
Status
Bar code PDF417: incorrect ECC level (Error Correction Level).
Measure
Alter ECC level.
8401 PDF417
Lines
Status
Bar code PDF417: illegal number of lines.
Measure
Alter number of lines.
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...