04/16 Rev. 11
USER + SERVICE MANUAL
/Status Reports
64-xx – DPM – PEM – ALX 73x (PMA) – LPA 81x (Printer) – ALX 92x – AP 5.4 – AP 5.6
48
5110 Foil
low
Status
The diameter of the foil roll fell below the set warning diameter (see
SYSTEM
PARAMETER > Foil warning
).
The message is caused by a foil warning in addition with the following
setting:
SYSTEM PARAMETER > Foil warn stop = „Enabled“
.
Measure
Acknowledge by pressing the Online button, then press the Feed button to
continue printing.
5120 Home
position
Status
The applied applicator cannot reach the home position; this can be caused
by an impact from outside (e.g. extending it manually), which has moved
the applicator. In those cases, the stepper motor looses steps and doesn´t
regain its home position.
Preconditions for this error to occur:
•
The parameter
DP INTERFACE > Interface type
is set to
USI Applicator
.
•
Internal inputs are enabled.
Measure
Take care not to move the applicator by force.
Ackknowledge by pressing the Online button.
5121 Touch
down
Status
The applied applicator doesn´t reach the Touch Down Position, what
means that it extends completely without reaching any product or other
resistance. .
Preconditions for this error to occur:
•
The parameter
DP INTERFACE > Interface type
is set to
USI Applicator
.
•
Internal inputs are enabled.
Measure
Correct the applicator position. The applicator must reach the product
before it is completely extended.
Ackknowledge by pressing the Online button.
5122
PLC not ready
Situation:
•
The parameter
DP INTERFACE > Interface type
is set to
USI Applicator
.
•
Internal inputs are enabled.
Status
The connected PLC is not on line.
Measure
Check if the PLC is powered on.
Check if the PLC shows any error status.
Ackknowledge by pressing the Online button.
5123
USI Material low
The error can only occur with an ALX 92x with optional OD control sensor.
Status
The outer diameter of the material roll has reached the set minimum value.
Measure
Insert a new material roll.
Ackknowledge by pressing the Online button.
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...