06/16 Rev. 09
SERVICE MANUAL
Service Mechanics
DPM – PEM – ALX 92x
23
6. Disconnect and remove the sensor cable.
7. Haltewinkel [41A] abschrauben (2 Schrau-
Assembling the retrofitting kit
1. Disassemble the dancer lever and the old
sensor (see above).
2. Push the axle [42A] through the bearing
block. Attach retaining washers on both
sides.
3. Attach the board holder [43A] to the base
plate with 3 screws.
Push the screws through the holes in the
bearing block [43B].
Notice the fitting position:
– RH: The leg with the single hole shows to
the
top
.
– LH: The leg with the single hole shows to
the
bottom
.
There must be a gap of 0.2 mm between
the surface of the magnet at the end of the
axle and the (outer) surface of the board
holder.
Continued overleaf.
[41] Unscrew the sensor holder (A).
B
A
[42] Axle with Hall sensor (A) ready assembled.
[43] Assemblilng the board holder (A).
[44] Checking the distance between magnet and holder surface.
A
A
B