06/16 Rev. 09
SERVICE MANUAL
Service Mechanics
DPM – PEM – ALX 92x
111
5. Connect the internal cable to connector
CN 701 on the CPU board [247A].
6. Attach respectively close the rear hood.
7. Plug in the remote operator panel. Switch
on the machine.
8. Operate the machine using the remote
operator panel. Print a service status print-
out (
PRINT INFO > Service status
).
The service printout must show the firm-
ware versions of both operator panels
[248A].
CAUTION!
Manipulating both operator panels si-
multaneously can cause malfuncti-
ons.
Always use only one operator panel at
a time to operate the machine (Using
both operator panels alternately is ad-
missible).
CAUTION!
If the connection cable is longer than
2.5 m, EMC-caused disturbances can
occur.
Only use the factory-installed cable.
Don´t extend the cable.
[247] Connector (A) for the remote operator panel on the CPU
board A6621 (CN 701).
[248] The service status printout shows the firmware for both
operator panels (A).
A
A