2.
Enter the
configure
command. The prompt changes to include (conf).
From this mode, you can enter INTERFACE mode by using the
interface
command.
CONTROL-PLANE Mode
To manage control-plane traffic, use CONTROL-PLANE mode. For more information, refer to
Control
Plane Policing (CoPP)
.
To enter CONTROL-PLANE mode:
1.
Verify that you are logged in to CONFIGURATION mode.
2.
Enter the
control-plane-cpuqos
command. The prompt changes to include (conf-control-
cpuqos).
You can return to CONFIGURATION mode by using the
exit
command.
DCB POLICY Mode
To enable and configure a Data Center Bridging (DCB) input or output policy, use DCB POLICY mode. For
more information, refer to
Data Center Bridging (DCB)
.
To enter DCB POLICY mode:
1.
Verify that you are logged in to CONFIGURATION mode.
2.
To enable or configure a DCB input policy, enter the
dcb-input
command then enter the policy
name. To enable or configure a DCB output policy, enter the
dcb-output
command then enter the
policy name. The prompt changes to include (conf-dcb-in) for an input policy or (conf-dcb-out) for
an output policy.
You can return to CONFIGURATION mode by using the
exit
command.
DHCP Mode
To enable and configure Dynamic Host Configuration Protocol (DHCP), use DHCP mode. For more
information, refer to
Dynamic Host Configuration Protocol (DHCP)
.
To enter DHCP mode:
1.
Verify that you are logged in to CONFIGURATION mode.
2.
Enter the
ip dhcp server
command. The prompt changes to include (config-dhcp).
You can return to CONFIGURATION mode by using the
exit
command.
DHCP POOL Mode
To create an address pool, use DHCP POOL mode. For more information, refer to
Dynamic Host
Configuration Protocol (DHCP)
.
To enter DHCP POOL mode:
1.
Verify that you are logged in to DHCP mode.
2.
Enter the
pool
command then the pool name. The prompt changes to include (config-dhcp-
pool-
name
).
You can return to DHCP mode by using the
exit
command.
52
CLI Basics
Summary of Contents for Networking S4810
Page 1: ...Dell Command Line Reference Guide for the S4810 System 9 4 0 0 ...
Page 42: ...42 ...
Page 62: ...62 ...
Page 89: ... 12946259 bytes successfully copied Dell reload File Management 89 ...
Page 90: ...90 ...
Page 164: ...164 ...
Page 204: ...204 ...
Page 348: ...348 ...
Page 518: ...518 ...
Page 614: ...614 ...
Page 652: ...652 ...
Page 674: ...Version 8 3 12 0 Introduced on the S4810 674 FCoE Transit ...
Page 686: ...686 ...
Page 828: ...828 ...
Page 838: ...838 ...
Page 1036: ...1036 ...
Page 1142: ...1142 ...
Page 1156: ...1156 ...
Page 1270: ...1270 ...
Page 1386: ...1386 ...
Page 1446: ...1446 ...
Page 1448: ...1448 ...
Page 1540: ...1540 ...
Page 1552: ...Gi 3 40 configured rate 16384 actual rate 16384 sub sampling rate 1 Dell 1552 sFlow ...
Page 1604: ...1604 ...
Page 1642: ...1642 ...
Page 1666: ...1666 ...
Page 1676: ...1676 ...
Page 1690: ...1690 ...
Page 1710: ...1710 ...