![Dell Networking S4810 Reference Manual Download Page 1066](http://html.mh-extra.com/html/dell/networking-s4810/networking-s4810_reference-manual_844971066.webp)
untagged
Add a Layer 2 interface to a VLAN as an untagged interface.
S4810
Syntax
untagged
interface
To remove an untagged interface from a VLAN, use the
no untagged
interface
command.
Parameters
interface
Enter the following keywords and slot/port or number
information:
• For a Port Channel interface, enter the keywords
port-
channel
then a number. The range is from 1 to 128.
• For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet
then the slot/port information.
• For a 40-Gigabit Ethernet interface, enter the keyword
fortyGigE
then the slot/port information.
Defaults
All interfaces in Layer 2 mode are untagged.
Command
Modes
INTERFACE VLAN
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant
Dell Networking OS Command Line Reference Guide
.
The following is a list of the Dell Networking OS version history for this command.
Version 9.0.2.0
Introduced on the S6000.
Version
8.3.19.0
Introduced on the S4820T.
Version 8.3.11.1
Introduced on the Z9000.
Version 8.5.1.0
Added support for 4-port 40G line cards on ExaScale.
Version 8.3.7.0
Introduced on the S4810.
Version 7.6.1.0
Introduced on the S-Series.
Version 7.5.1.0
Introduced on the C-Series.
pre-Version
6.2.1.1
Introduced on the E-Series.
Usage
Information
Untagged interfaces can only belong to one VLAN.
In the Default VLAN, you cannot use the
no untagged interface
command. To
remove an untagged interface from all VLANs, including the Default VLAN, enter
INTERFACE mode and use the
no switchport
command.
1066
Layer 2
Summary of Contents for Networking S4810
Page 1: ...Dell Command Line Reference Guide for the S4810 System 9 4 0 0 ...
Page 42: ...42 ...
Page 62: ...62 ...
Page 89: ... 12946259 bytes successfully copied Dell reload File Management 89 ...
Page 90: ...90 ...
Page 164: ...164 ...
Page 204: ...204 ...
Page 348: ...348 ...
Page 518: ...518 ...
Page 614: ...614 ...
Page 652: ...652 ...
Page 674: ...Version 8 3 12 0 Introduced on the S4810 674 FCoE Transit ...
Page 686: ...686 ...
Page 828: ...828 ...
Page 838: ...838 ...
Page 1036: ...1036 ...
Page 1142: ...1142 ...
Page 1156: ...1156 ...
Page 1270: ...1270 ...
Page 1386: ...1386 ...
Page 1446: ...1446 ...
Page 1448: ...1448 ...
Page 1540: ...1540 ...
Page 1552: ...Gi 3 40 configured rate 16384 actual rate 16384 sub sampling rate 1 Dell 1552 sFlow ...
Page 1604: ...1604 ...
Page 1642: ...1642 ...
Page 1666: ...1666 ...
Page 1676: ...1676 ...
Page 1690: ...1690 ...
Page 1710: ...1710 ...