Version 8.3.11.1
Introduced on the Z9000.
Version 8.3.7.0
Introduced on the S4810.
ipv6 nd prefix
Specify which IPv6 prefixes are included in Neighbor Advertisements.
S4810
Syntax
ipv6 nd prefix {
ipv6-prefix
|
prefix-length
| default} [no-
advertise] | [no-autoconfig] [no-rtr-address] [off-link]
[lifetime {
valid
| infinite} {
preferred
| infinite}]
Parameters
ipv6-prefix
Enter an IPv6 prefix.
prefix-length
Enter the prefix then the prefix length. The length range is
from 0 to 128.
default
Enter the keyword
default
to set default parameters for all
prefixes.
no-advertise
Enter the keyword
no-advertise
to prevent the specified
prefix from being advertised.
no-autoconfig
Enter the keywords
no-autoconfig
to disable Stateless
Address Autoconfiguration.
no-rtr-address
Enter the keyword
no-rtr-address
to exclude the full
router address from router advertisements (the R bit is not
set).
off-link
Enter the keywords
off-link
to advertise the prefix without
stating to recipients that the prefix is either on-link or off-
link.
valid-lifetime
|
infinite
Enter the amount of time that the prefix is advertised, or
enter
infinite
for an unlimited amount of time. The range
is from 0 to 4294967295. The default is
2592000
. The
maximum value means that the preferred lifetime does not
expire for the valid-life time parameter.
preferred-
lifetime
|
infinite
Enter the amount of time that the prefix is preferred, or enter
infinite
for an unlimited amount of time. The range is
from 0 to 4294967295. The default is
604800
. The
maximum value means that the preferred lifetime and does
not expire.
Command
Modes
INTERFACE
934
IPv6 Basics
Summary of Contents for Networking S4810
Page 1: ...Dell Command Line Reference Guide for the S4810 System 9 4 0 0 ...
Page 42: ...42 ...
Page 62: ...62 ...
Page 89: ... 12946259 bytes successfully copied Dell reload File Management 89 ...
Page 90: ...90 ...
Page 164: ...164 ...
Page 204: ...204 ...
Page 348: ...348 ...
Page 518: ...518 ...
Page 614: ...614 ...
Page 652: ...652 ...
Page 674: ...Version 8 3 12 0 Introduced on the S4810 674 FCoE Transit ...
Page 686: ...686 ...
Page 828: ...828 ...
Page 838: ...838 ...
Page 1036: ...1036 ...
Page 1142: ...1142 ...
Page 1156: ...1156 ...
Page 1270: ...1270 ...
Page 1386: ...1386 ...
Page 1446: ...1446 ...
Page 1448: ...1448 ...
Page 1540: ...1540 ...
Page 1552: ...Gi 3 40 configured rate 16384 actual rate 16384 sub sampling rate 1 Dell 1552 sFlow ...
Page 1604: ...1604 ...
Page 1642: ...1642 ...
Page 1666: ...1666 ...
Page 1676: ...1676 ...
Page 1690: ...1690 ...
Page 1710: ...1710 ...