2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
646
List Manual, 09/2017, A5E33842890
Description:
Sets the signal source for the input pulse I of instance PDF 1 of the breaking delay device.
Description:
Setting parameter for pulse extension time T in milliseconds of instance PDF 1 of the breaking delay device.
Description:
Display parameter for output pulse Q of instance PDF 1 of the breaking delay device.
Description:
Setting parameter for the run-time group in which the instance PDF 1 of the breaking delay device is to be called.
Value:
5:
Run-time group 5
6:
Run-time group 6
9999: Do not calculate
p20173
BI: PDF 1 input pulse I / PDF 1 inp_pulse I
CU250S_V
(FBLOCKS)
CU250S_V_CAN
(FBLOCKS)
CU250S_V_DP
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7233
Min Max
Factory
setting
- - 0
p20174
PDF 1 pulse extension time in ms / PDF 1 t_ext ms
CU250S_V
(FBLOCKS)
CU250S_V_CAN
(FBLOCKS)
CU250S_V_DP
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7233
Min Max
Factory
setting
0.00 5400000.00
0.00
r20175
BO: PDF 1 output Q / PDF 1 output Q
CU250S_V
(FBLOCKS)
CU250S_V_CAN
(FBLOCKS)
CU250S_V_DP
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7233
Min Max
Factory
setting
- - -
p20176
PDF 1 run-time group / PDF 1 RTG
CU250S_V
(FBLOCKS)
CU250S_V_CAN
(FBLOCKS)
CU250S_V_DP
(FBLOCKS)
CU250S_V_PN
(FBLOCKS)
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7233
Min Max
Factory
setting
5 9999
9999
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......