SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
533
2 Parameters
2.2 List of parameters
Description:
Sets the station name for the onboard PROFINET interface on the Control Unit.
The actual station name is displayed in r8930.
Dependency:
Refer to: p8925, r8930
Note:
An ASCII table (excerpt) can be found, for example, in the appendix to the List Manual.
The interface configuration (p8920 and following) is activated with p8925.
The parameter is not influenced by setting the factory setting.
PN: PROFINET
Description:
Sets the IP address for the onboard PROFINET interface on the Control Unit.
The actual IP address is displayed in r8931.
Dependency:
Refer to: p8925, r8931
Note:
The interface configuration (p8920 and following) is activated with p8925.
The parameter is not influenced by setting the factory setting.
Description:
Sets the default gateway for the onboard PROFINET interface on the Control Unit.
The actual standard gateway is displayed in r8932.
Dependency:
Refer to: p8925, r8932
Note:
The interface configuration (p8920 and following) is activated with p8925.
The parameter is not influenced by setting the factory setting.
Description:
Sets the subnet mask for the onboard PROFINET interface on the Control Unit.
The actual subnet mask is displayed in r8933.
Dependency:
Refer to: p8925, r8933
Note:
The interface configuration (p8920 and following) is activated with p8925.
The parameter is not influenced by setting the factory setting.
p8920[0...239]
PN Name of Station / PN Name Stat
CU250S_V_PN
Access level:
3
Calculated:
-
Data type:
Unsigned8
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
p8921[0...3]
PN IP address / PN IP addr
CU250S_V_PN
Access level:
3
Calculated:
-
Data type:
Unsigned8
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 255
0
p8922[0...3]
PN Default Gateway / PN Def Gateway
CU250S_V_PN
Access level:
3
Calculated:
-
Data type:
Unsigned8
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 255
0
p8923[0...3]
PN Subnet Mask / PN Subnet Mask
CU250S_V_PN
Access level:
3
Calculated:
-
Data type:
Unsigned8
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 255
0
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......