SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
427
2 Parameters
2.2 List of parameters
Dependency:
Refer to: p2571, p2585, p2586, p2605, p2618, p2643, r2681
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
The effective override (r2681) can differ from the specified override due to limits (e.g. maximum velocity).
Description:
Sets the signal source for selecting the operating mode "direct setpoint input/MDI".
Dependency:
Refer to: p2640, p2641, p2642, p2643, p2644, p2645, p2646, p2648, p2649, p2650, p2651, p2652, p2653
Note:
In this mode, using BI: p2653 it is possible to make a flying changeover between setting-up and positioning.
In this mode, even if the axis is not referenced (r2684.11 = 0) relative positioning is possible.
Description:
Sets the signal source for the positioning type in the mode "direct setpoint input/MDI".
BI: p2648 = 1 signal
Absolute positioning is selected.
BI: p2648 = 0 signal
Relative positioning is selected.
Dependency:
Refer to: p2649, p2650, p2654
Refer to: A07461, F07488
Notice:
Absolute positioning:
To traverse, the reference point must be set (r2684.11 = 1).
Relative positioning:
To traverse, it is not necessary that the reference point is set.
Note:
Depending on p2649, the positioning type is either transferred continuously or edge-triggered.
Binector input p2648 is only evaluated when connector input p2654 = 0. If p2654 is a value other than 0, the
positioning type is evaluated by means of the set signal source.
Description:
Sets the signal source to define how values are transferred in the operating mode "direct setpoint input/MDI".
BI: p2649 = 1 signal
Values are continually transferred (refer to parameter under dependency).
BI: p2649 = 0 signal
The values are transferred for BI: p2650 = 0/1 signal.
Dependency:
Refer to: p2642, p2643, p2644, p2645, p2648, p2650, p2651, p2652
Caution:
For BI: p2649 = 1 signal, the following applies:
Motion starts without any explicit control signal.
p2647
BI: EPOS direct setpoint input/MDI selection / MDI selection
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3620, 3625, 3640
Min Max
Factory
setting
- - 0
p2648
BI: EPOS direct setpoint input/MDI positioning type / MDI pos_type
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3620
Min Max
Factory
setting
- - 0
p2649
BI: EPOS direct setpoint input/MDI transfer type selection / MDI trans_type sel
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3620
Min Max
Factory
setting
- - 0
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......