2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
440
List Manual, 09/2017, A5E33842890
Description:
Sets a fixed setpoint for the deceleration override.
Dependency:
Refer to: p2573, p2645
Note:
As standard, the following BICO interconnection is established: CI: p2645 = r2693
The percentage value refers to the maximum deceleration (p2573).
Description:
Sets the configuration for position tracking of a load gear.
Note:
For the following events, the non-volatile, saved position values are automatically reset:
- when an encoder replacement has been identified.
- when changing the configuration of the Encoder Data Set (EDS).
- when adjusting the absolute encoder again
Description:
Sets the number of rotations that can be resolved for a rotary absolute encoder with activated position tracking of the
load gear.
Dependency:
This parameter is only of significance for an absolute encoder (p0404.1 = 1) with activated position tracking of the
load gear (p2720.0 = 1).
Note:
The resolution that is set must be able to be represented using r2723.
For rotary axes/modulo axes, the following applies:
This parameter is pre-set with p0421 when activating position tracking and can be changed.
For linear axes, the following applies:
This parameter is pre-assigned with p0421 when activating position tracking, expanded by 6 bits for multiturn
information (maximum number of overflows) and cannot be changed.
p2693
CO: EPOS deceleration override, fixed setpoint / -a_over fixed val
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3618
Min Max
Factory
setting
0.100 [%]
100.000 [%]
100.000 [%]
p2720[0...n]
Load gear configuration / Load gear config
Access level:
1
Calculated:
-
Data type:
Unsigned32
Can be changed:
C(1)
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - 0000
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Load gear activate position tracking
Yes
No
-
01
Axis type
Linear axis
Rotary axis
-
02
Load gear reset position
Yes
No
-
p2721[0...n]
Load gear rotary absolute encoder revolutions virtual / Abs rot rev
Access level:
1
Calculated:
-
Data type:
Unsigned32
Can be changed:
C(1)
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 4194303
0
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......