SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
419
2 Parameters
2.2 List of parameters
Description:
Sets the acceleration override for the traversing block.
The override refers to the maximum acceleration (p2572).
Dependency:
The number of indices depends on p2615.
Refer to: p2572, p2615, p2616, p2617, p2618, p2620, p2621, p2622, p2623, p2624
Description:
Sets the deceleration override for the traversing block.
The override refers to the maximum deceleration (p2573).
Dependency:
The number of indices depends on p2615.
Refer to: p2573, p2615, p2616, p2617, p2618, p2619, p2621, p2622, p2623, p2624
Notice:
If, when calculating the traversing profile, it is identified that the target position of the next block with the programmed
deceleration override will not be reached without direction reversal (flying block change), then the old (actual)
deceleration override remains effective.
Description:
Sets the required task for the traversing block.
Value:
1:
POSITIONING
2:
FIXED STOP
3:
ENDLESS_POS
4:
ENDLESS_NEG
5:
WAITING
6:
GOTO
7:
SET_O
8:
RESET_O
9:
JERK
Dependency:
The number of indices depends on p2615.
Refer to: p2615, p2616, p2617, p2618, p2619, p2620, p2622, p2623, p2624
p2619[0...n]
EPOS traversing block acceleration override / Trav_block a_over
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
p2615
Unit group:
-
Unit selection:
-
Func. diagram:
3616
Min Max
Factory
setting
1.0 [%]
100.0 [%]
100.0 [%]
p2620[0...n]
EPOS traversing deceleration override / Trav_block -a_over
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
p2615
Unit group:
-
Unit selection:
-
Func. diagram:
3616
Min Max
Factory
setting
1.0 [%]
100.0 [%]
100.0 [%]
p2621[0...n]
EPOS traversing block task / Trav_block task
CU250S_V (EPOS)
CU250S_V_CAN
(EPOS)
CU250S_V_DP
(EPOS)
CU250S_V_PN
(EPOS)
Access level:
1
Calculated:
-
Data type:
Integer16
Can be changed:
U, T
Scaling:
-
Dyn. index:
p2615
Unit group:
-
Unit selection:
-
Func. diagram:
3616
Min Max
Factory
setting
1 9 1
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......