SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
559
2 Parameters
2.2 List of parameters
Note:
SAM: Safe Acceleration Monitor (safe acceleration monitoring)
SSM: Safe Speed Monitor (safety-relevant feedback signal from the speed monitoring)
Description:
Sets the velocity hysteresis for the SSM feedback signal to detect standstill (n < nx).
Dependency:
Refer to: C01711
Note:
The velocity hysteresis is effective only if the function is enabled (p9501.16 = 1).
The parameter is included in the data cross-check of the two monitoring channels.
SSM: Safe Speed Monitor (safety-relevant feedback signal from the speed monitoring)
Description:
Sets the velocity tolerance for the "SAM" function.
Dependency:
Refer to: C01706
Note:
SAM: Safe Acceleration Monitor (safe acceleration monitoring)
Description:
Sets the delay time for the SLS changeover for the function "Safely Limited Speed" (SLS).
When transitioning from a higher to a lower safely limited velocity/speed stage, within this delay time, the "old"
velocity stage remains active.
Even if SLS is activated from the state "SLS in active", then this delay is still applied.
Note:
SLS: Safely Limited Speed
Description:
Sets the delay time for STOP A after STOP B.
Dependency:
Refer to: p9560
Refer to: C01701
Note:
The set time is rounded internally to an integer multiple of the monitoring clock cycle.
p9547
SI Motion SSM velocity hysteresis (processor 1) / SI Mtn SSM hyst P1
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2823
Min Max
Factory
setting
0.0010 [rpm]
500.0000 [rpm]
10.0000 [rpm]
p9548
SI Motion SAM actual speed tolerance (processor 1) / SI mtn SAM tol P1
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0.00 [rpm]
120000.00 [rpm]
300.00 [rpm]
p9551
SI Motion SLS changeover delay time (processor 1) / SI Mtn SLS t P1
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2819, 2820
Min Max
Factory
setting
0.00 [ms]
600000.00 [ms]
100.00 [ms]
p9556
SI Motion pulse suppression delay time (processor 1) / SI Mtn IL t_del P1
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2819
Min Max
Factory
setting
0.00 [ms]
3600000.00 [ms]
600000.00 [ms]
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......