SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
105
2 Parameters
2.2 List of parameters
Description:
Sets the signal source for the encoder control word Gn_STW according to PROFIdrive.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Description:
Sets the signal source for the encoder control word Gn_STW according to PROFIdrive.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Description:
Displays the encoder status word Gn_ZSW according to PROFIdrive.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Notice:
Information on Gn_STW/Gn_ZSW can, e.g. be found in the following literature:
SINAMICS S120 Function Manual Drive Functions
p0480[0...2]
CI: Encoder control word Gn_STW signal source / Enc Gn_STW S_src
Access level:
3
Calculated:
-
Data type:
U32 / Integer16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4720, 4750
Min Max
Factory
setting
- - [0]
0
[1] 0
[2] 0
p0480[0...2]
CI: Encoder control word Gn_STW signal source / Enc Gn_STW S_src
CU250S_V (Position
control)
CU250S_V_CAN
(Position control)
CU250S_V_DP
(Position control)
CU250S_V_PN
(Position control)
Access level:
3
Calculated:
-
Data type:
U32 / Integer16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4720, 4750
Min Max
Factory
setting
- - [0]
2520[0]
[1] 2520[1]
[2] 2520[2]
r0481[0...2]
CO: Encoder status word Gn_ZSW / Enc Gn_ZSW
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4010, 4704, 4730,
4750
Min Max
Factory
setting
- - -
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Function 1 active
Yes
No
-
01
Function 2 active
Yes
No
-
02
Function 3 active
Yes
No
-
03
Function 4 active
Yes
No
-
04
Value 1
Displayed in r0483
Not present
-
05
Value 2
Displayed in r0483
Not present
-
06
Value 3
Displayed in r0483
Not present
-
07
Value 4
Displayed in r0483
Not present
-
08
Measuring probe 1 deflected
Yes
No
-
09
Measuring probe 2 deflected
Yes
No
-
11
Encoder fault acknowledge active
Yes
No
9676
13
Absolute value cyclically
Displayed in r0483
No
-
14
Parking encoder active
Yes
No
-
15
Encoder fault
Displayed in r0483
None
-
Содержание SINAMICS G120
Страница 1: ...SINAMICS SINAMICS G120 CU250S 2 Control Units List Manual 09 2017 Edition www siemens com drives ...
Страница 2: ......
Страница 726: ...2 Parameters 2 6 Quick commissioning p0010 1 SINAMICS G120 CU250S 2 Control Units 726 List Manual 09 2017 A5E33842890 ...
Страница 990: ...3 Function diagrams 3 26 Data sets SINAMICS G120 CU250S 2 Control Units 990 List Manual 09 2017 A5E33842890 ...
Страница 1242: ...A Appendix A 2 List of abbreviations SINAMICS G120 CU250S 2 Control Units 1242 List Manual 09 2017 A5E33842890 ...
Страница 1255: ......